Easy to Use
Ready-to-use reagents, adapter free one-grip loading of reagent containers, integrated bar code reader for sample and reagent as well as the intuitive software alleviates daily workload significantly.
Competitive and Unique
Minimized service and maintenance costs, low reagent consumption and high on board-stability of DiaSys system reagents in combination with highest result safety add up for a highly competitive system. Further features like LIS-connectivity, clot detection and crash sensor make respons®910 unique in its class.
respons®910 up – The new generation of automated testing
The new software version 4.8.0.8 is available for respons®910 devices. DiaSys highly recommends to up-grade all installed respons®910 analyzers because it eases daily laboratory routine. This new software leads to up-dated reliability and offers new and improved functionality as:
- Improvement of 2 µl sample pipetting precision
- Modified cuvette acceptance criteria
- Extended carry over evasion
- Protecting your DiaSys reagent business by closing of channels
- General handling improvements and bug fixes
Technical Specifications
System type | Bench top clinical chemistry analyzer |
Throughput | 150 tests/hour for mono-reagents; 100 tests/hour for 2 component reagents |
Combined reagent/sample tray | 30 reagent positions plus 30 patient sample positions, easy removable tray for storage in refrigerator |
Sample types | Serum, plasma, whole blood,urine, CSF |
Sample volume | 2 – 30 μL |
Reagent pipetting volume | Reagent 1: 120 – 250 μL Reagent 2: 10 – 50 μL |
STAT-analytics | 2 sample positions for loading of emergency samples at any time |
Ion measurement | Enzymatic tests for Cl, K, Na, Li |
Bar code identification | Automatic bar code scan for reagents and samples |
Measuring principle | Colorimetry (Rate/End Point); Turbidimetric Immunoassay |
Calibration | Linear, non-linear, multi-point |
Sample tubes/cups | Primary tubes of 5, 7 and 10 mL and sample cups |
Reagent on-board capacity | 30 different methods in bar coded mono- or twin-containers for adapter-free one-grip loading |
Reaction temperature | 37 ± 0.2 °C |
Reaction unit | Temperature controlled heated rotor with 105 disposable plastic cuvettes (37 ± 0.2 °C) |
Photometry | 12 wavelengths: 340, 380, 405, 450, 480, 508, 546, 570, 600, 660, 700 and 800 nm (mono- and bichromatic) |
Photometric linearity and resolution | 0 – 3.0 OD; resolution: 0.0001 OD |
Water consumption | < 1 liter per hour |
LIS connectivity | Given |
System interface | Analyzer – PC: USB connectivity bi-directional; CPU: Pentium IV or higher |
Power source/power consumption | AC 110/220 V, 60/50 Hz; 300 VA excluding PC/printer/monitor |
Dimensions | 60 cm (W) x 67 cm (D) x 60 cm (H) |
Weight | Approximately 60 kg |